Applications
- Steam pipelines in petroleum production, pre-insulated pipes
- Power plants, petrochemical plants, chemical plants
- Tanks and containers
- Ovens and furnaces
- Trains and vehicles
- Buildings and constructions
Physical Properties
Product Form | Roll |
Standard Thickness | 3mm, 6mm, 10mm |
Max Width | 1500mm |
Thermal Conductivity | 0.017w/m·k (at 30℃) |
Max Use Temperature | 650℃ |
Density | 200 ± 30 kg/m3 |
Hydrophobic | Yes |
AMA AEROGEL BLANKET HT650
High Performance Insulation Blanket for Industrial Applications and Building & Construction Sector
- Superior Insulation Performances
2~5 times better insulation performance than traditional materials, achieving same and even better insulation performance with minimum insulation thickness
- Hydrophobic but Vapor Permeable
Water repellency and vapor permeability help to prevent Corrosion Under Insulation(CUI)
- Compression Resistent yet resilient
Compression resistance and bounce-back allow recovering thermal performance after being compressed
- Inorganic and Inflammable Profile
Enables stable performance over long term while providing fire protection to objects
- Easy for Handling and Installation
Can be cut on site easily with conventional cutting tools to fit any specific shape or geometry
- Less Volume for Storage and Transportation
Less volume needed for insulation materials, sharply reducing volume and cost for storage and transportation
- Enviromentally Safe
No respirable fiber content, directly landfill disposable
AMA AEROGEL BLANKET HT650 Series is a high performance insulation blanket composed of silica aerogel, which is the lowest thermal conductor in the world, and non woven glass fiber batting blanket, suitable for the industrial applications with a temperature range between -50℃ to +650℃; it’s also suitable for building & construction sector.
Being super low thermal conductive, hydrophobic yet vapor permeable, compression resistant and resilient, inorganic and inflammable profile, easy processing with reduced volume, and environmentally safe. AMA AEROGEL BLANKET HT650 Series is the state-of-art product which is the perfect choice for those in need of the best insulation performance with minimum thickness while achieving minimum energy consumption. It is suitable for the insulation of pipes, tanks, containers and other industrial applications for the thermal protection and fireproofing.
AMA AEROGEL BLANKET HT650 is the perfect solution for those who need to improve the performance of insulation and significantly reduce energy consumption.
Aerogel is the material with the lower coefficient of thermal conductivity currently on the market. The combination of the granule of Aerogel with resistant glass fibers, make AMA AEROGEL BLANKET HT650 a flexible material, environmentally friendly, easy handling and processing, as to make it the industry leader.
(3mm – 6mm – 10mm)
Açıklama
- IDENTIFICATION OF PRODUCTS AND MANUFACTURER
Name: | AMA Aerogel 450® |
Acronim: | Silica Aerogel |
Supplier: | AMA Composites Srl |
Adress: | Via Repubblica 7 41011 Campogalliano (MO) |
Email: | info@amaaerogel.com |
Telephone number for emergency: | Centro Antiveleni Ospedale Niguarda Milano
02-66101029 24H
|
- COMPOSITION/INFORMATION ON INGREDIENTS
Ingredient |
CAS Number | EINECS Number | Percent |
Amorphous silica | 112945-52-5 | 231-545-4 | 35-60% |
Glass fiber | None | None | 20-50% |
Al2O3 | 1344-28-1 | 215-691-6 | 5-10% |
- HAZARDS IDENTIFICATION
POTENTIAL HEALTH EFFECTS:
Product is not classified as a dangerous material or preparation as defined in National List of Hazardous Chemicals, in GB 6944-2005 Classification and Number of Hazardous Chemicals and in Registration, Evaluation, Authorization and Restriction of Chemicals (REACH).
CARCINOGENICITY:
Component | ACGIH | IARC |
Amorphous silica | None | None |
Glass fiber | A4 | 3 |
Al2O3 | Not Listed | None |
ACGIH: American Conference of Governmental Industrial Hygienists
IARC: International Agency for Research on Cancer
Eye Contact: Exposure to dust from this product can produce a drying sensation and irritation of the eyes. Seriously, it can cause pain and redness.
Skin Contact: Skin contact with dust from this product can produce a drying sensation and irritation of the skin and mucous membranes. Excessive contact may aggravate existing dermatitis.
Ingestion: This material is not intended to be eaten. If ingested in large quantity, the material may produce irritation and blockage.
Inhalation: Inhalation of airborne dusts may cause irritation of the upper respiratory tract. Excessive inhalation may aggravate pre-existing chronic lung conditions including, but not limited to, bronchitis, emphysema, and asthma.
Environmental hazards: No harm to the environment as per National Catalogue of Hazardous Wastes.
Explosion Hazards: This product is not flammable, but the plastic encapsulations will burn in the event of fire.
- FIRST AID MEASURES
Eye Contact: Immediately wash with large amounts of water for at least 15 minutes, occasionally lifting lids. If irritation occurs and persists, get medical treatment.
Skin Contact: Remove contaminated clothing and shoes, and wash skin thoroughly with soap and plenty of water. Wash clothing before reuse.
Ingestion: If symptoms persist, seek medical attention immediately.
Inhalation: Remove to fresh air. If symptoms persist, seek medical attention immediately.
5. FIRE-FIGHTING MEASURES
FLAMMABILITY PROPERTIES:
Auto ignition Temperature: Not Applicable
Flash Point: Not Applicable
Flammability Limits: (Lower Explosive Limit): Not Applicable
Flammability Limits: (Upper Explosive Limit): Not Applicable
Harmful Combustion Products: In the scene of a fire, primary combustion products are carbon monoxide, carbon dioxide and dihydrogen oxide.
Fire Fighting Procedures: Normal fire fighting procedures should be followed to avoid inhalation of smoke and gases produced by a fire. Protective clothing are needed. Firefighters should stand in the tuyere, and use the fire-fighting facilities for surrounding environment.
Suitable extinguishing agent: Dry powder, foam, mist shape water or carbon dioxide
Hazards: The product is a super-insulation material. Rolls of material can retain heat within internal layers and re-ignite combustible materials if heat is not removed.
- ACCIDENTAL RELEASE MEASURES
Personal Protective: Chemical protective clothes and dustproof mask are needed(full cover).
Environmental Precautions: Insoluble in water. It is strictly prohibited to environmental emissions without treatment to avoid block.
NOTES: Powder and fragments should be cleaned up using a method that will avoid the creation of dust in the workplace atmosphere. A vacuum cleaner is recommended.
7.HANDING AND STORAGE
Handling: Aerogel blankets will generate dust when handled. Workplace exposure to all dusts should be controlled with standard industrial hygiene practices. Because aerogel dust is hydrophobic, dry vacuuming is the preferred method for cleaning up dust.
It is suggested to wear approved respiratory protective equipment, protective glasses and gloves. Don’t make dust touches the skin, eyes or clothes. Clean thoroughly after handing.
Storage: It should be stored in cool, dry and ventilated warehouse.
Aerogel blankets should be kept in their packaging until they are ready to be used. It will help to minimize the area where dust exposure may occur.
The waste after cutting should be promptly packed in disposal bags.
- TOXICOLOGICAL INFORMATION
ACUTE TOXICITY: Dust may cause irritation and dryness to eyes and skin.
Amorphous Silica:
LD50: >5,000 mg/kg(Oral)
LC50: >2,000 mg/m3(Inhalation)
LD50: >3,000 mg/kg(Dermal)
Eye Irritation: It is not irritating to eyes under experimental conditions, but may produce dryness following prolonged and repeated exposure.
Skin Irritation: It is not irritating to skin under experimental conditions, but may produce dryness following prolonged and repeated exposure.
Aluminum oxide LD50: >5,000 mg/kg(Oral)
Eye Irritation: Slightly irritating。
Skin Irritation: Non-irritating
Reproductive Toxicity: None
Carcinogenicity: None.
Mutation: None
Teratogenic toxicity: None
- ECOLOGICAL INFORMATION
Aquatic Toxicity
Amorphous Silica Fish: LC50 > 10,000 mg/L (Brachydanio rerio: 96 hour), Method OECD 203
Daphnia magna: EC50 > 10,000 mg/l (24 hours), Method OECD 202
Aluminum oxide Fish: LC50 > 10,000 mg/L
Persistence and Biodegradability: Not applicable for inorganic material.
Bioaccumulative Potential: None, due to insoluble nature of product.
Other Adverse Effects: None.
- DISPOSAL CONSIDERATIONS
WASTE DISPOSAL METHOD: It is not classified as hazardous waste, and can be disposed of at a normal landfill site that has been licensed for the disposal of industrial waste.
- TRANSPORT INFORMATION
Shipping Name: Not regulated for transport
Hazard Class: None
UN Number: None
Packing Group: None
Required Label(s): None
Additional Information: None
NOTES: Try to keep packing integrity, and avoid dust, heat, and fire on the prescribed route. Organic solvents are not allowed to be mix shipped with.
15.REGULATION INFORMATION
Regulations on the Safety Use of Chemicals in Workplace (File No.423 by Ministry of Labor in 1996)
Classification and Mark of Common Dangerous Chemicals (No.344 by the State Council of PRC)
National Catalogue of Hazardous Wastes (2008 Appendix by Ministry of Environmental Protection)
Catalogue of Dangerous Chemicals (2002 Edition)
GB 6944-2005 Classification and code of dangerous goods
Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
American Conference of Governmental Industrial Hygienists (ACGIH)
International Agency for Research on Cancer (IARC)
Occupation al Safety and Health Act (OSHA)
- OTHER INFORMATION
For purposes of this MSDS, International Specialty Products, as responsible party, provides the information herein which is intended for use by persons who have or should obtain professional knowledge and experience in the subjects discussed. AMAComposites industrial products are used as materials in the production of products by industrial customers.
AMA Composites makes no warranty, express or implied, as to the accuracy, completeness or reliability of information herein except that such information is, to the best of our knowledge and belief, accurate as of the date indicated. AMA Composites recommends that customers independently test and evaluate its products and their products and processes in which our products are used in order to decide their safety and effectiveness.
- EXPOSURE CONTROLS/PERSONAL PROTECTION
Exposure Limit Values
AVERAGE VALUE (8 HOURS) | |||||
Component | CAS Number | US OSHA PEL(TWA) | UK WEL | ||
Total inhalable fraction | Inhalable fraction | Total inhalable fraction | Inhalable fraction | ||
Amorphous silica | 112945-52-5
68909-20-6 |
15mg/m3 | 5mg/m3 | 6mg/m3 | 2.4mg/m3 |
Al2O3 | 1344-28-1 | 15mg/m3 | 5mg/m3 | 10mg/m3 | 4mg/m3 |
Glass fiber | —— | 5mg/ m3 | 2mg/ m3 | —— | —— |
Ventilation: Local exhaust in accordance with general industrial hygiene practices is recommended to control dust.
Respiratory Protection: A properly fitted, NIOSH or CE approved respirator should be worn.
Eye Protection: Safety glasses, or chemical goggles as needed to provide greater protection from dust.
Skin Protection: Nitrile, latex, or other impermeable coat should be worn when handling aerogel blankets.
Hand Protection: Nitrile, latex, or other impermeable gloves should be worn when handling aerogel blankets.
Other Protection: Keep a good Hygienic Practice. Smoking, eating and drinking are not allowed in work area. Wash hands before eating or drinking. Wash thoroughly after using the product.
- PHYSICAL AND CHEMICAL PROPERTIES
Appearance: White fabric blanket
PH: Not applicable
Boling Point Not applicable
Relative density (water=1) Not applicable
Melting Point: Not applicable
Vapor pressure: Not applicable
Solubility: Insoluble
Key property: Insulation
- STABILITY AND REACTIVITY
Chemical stability: Stable
Materials to Avoid: Organic solvent.
Conditions to Avoid: Temperatures above the recommended use temperature
Hazardous: None
Decomposition products: Primary combustion products are carbon monoxide, carbon dioxide and dihydrogen oxide.
Applications
- Pipelines and equipment in cold insulation
- Biological medicine equipment
- Liquid nitrogen
- LNG
Physical Properties
Product Form | Roll |
Standard Thickness | 3mm, 6mm, 10mm |
Max Width | 1500mm |
Thermal Conductivity | 0.010 Wm·k (-200℃) |
Max Use Temperature | +100℃ |
Density | 200 ± 30 kg/m3 |
Hydrophobic | Yes |
AMA AEROGEL BLANKET LT200ALU
High Performance Insulation Blanket for cryogenic Applications and cold insulation
- Superior Insulation Performances
2~5 times better insulation performance than traditional materials, achieving same and even better insulation performance with minimum insulation thickness
- Hydrophobic with aluminium foil Vapor Barrier
Water repellency and vapor barrier made by aluminium foil help to prevent Corrosion Under Insulation (CUI)
- Compression Resistant yet resilient
Compression resistance and bounce-back allow recovering thermal performance after being compressed
- Inorganic and Inflammable Profile
Enables stable performance over long term while providing fire protection to objects
- Easy for Handling and Installation
Can be cut on site easily with conventional cutting tools to fit any specific shape or geometry
- Less Volume for Storage and Transportation
Less volume needed for insulation materials, sharply reducing volume and cost for storage and transportation
- Enviromentally Safe
No respirable fiber content, directly landfill disposable
AMA AEROGEL BLANKET HT650N Series is a high performance insulation blanket composed of silica aerogel, which is the lowest thermal conductor in the world, and non woven glass fiber batting blanket, suitable for the cold applications with a temperature range between -200℃ to +100℃.
Being super low thermal conductive, hydrophobic yet vapor permeable, compression resistant and resilient, inorganic and inflammable profile, easy processing with reduced volume, and environmentally safe. AMA AEROGEL BLANKET LT200ALU Series is the state-of-art product which is the perfect choice for those in need of the best insulation performance with minimum thickness while achieving minimum energy consumption. It is suitable for the insulation of pipes, tanks, containers and other industrial applications for the thermal protection. AMA AEROGEL BLANKET LT200ALU is the perfect solution for those who need to improve the performance of insulation and significantly reduce energy consumption.
Aerogel is the material with the lower coefficient of thermal conductivity currently on the market. The combination of the granule of Aerogel with resistant glass fibers, make AMA AEROGEL BLANKET LT200ALU a flexible material, environmentally friendly, easy handling and processing, as to make it the industry leader.
Applications
- Steam pipelines in petroleum production, pre-insulated pipes ·Power plants, petrochemical plants, chemical plants
- Tanks and containers
- Ovens and furnaces
- Trains and vehicles ·Buildings and constructions
Physical Properties
Product Form | Roll |
Standard Thickness | 10mm |
Max Width | 1500mm |
Thermal Conductivity | 0.021w/m·k (at 25°C) |
Max Use Temperature | +1000°C |
Density | 220 ± 20 kg/m3 |
Hydrophobic | No |
AMAGEL HT1000
High Performance Insulation Blanket for High-Temp Industrial Applications
- Superior Insulation Performances
2~5 times better insulation performance than traditional materials, achieving same and even better insulation performance with minimum insulation thickness
- Vapor Permeable
Vapor permeability help to prevent Corrosion Under Insulation(CUI)
- Compression Resistent yet resilient
Flexibility and bounce-back allow recovering thermal performance after being compressed
- Inorganic and Inflammable Profile
Enables stable performance over long term while providing fire protection to objects
- Easy for Handling and Installation
Can be cut on site easily with conventional cutting tools to fit any specific shape or geometry
- Less Volume for Storage and Transportation
Less volume needed for insulation materials, sharply reducing volume and cost for storage and transportation
- Enviromentally Safe
No respirable fiber content, directly landfill disposable
AMAGEL HT1000 Series is a high performance insulation blanket composed of silica aerogel, which is the lowest thermal conductor in the world, and of special high temperature glass fiber, suitable for the high temperature industrial applications between 0°C to +1000°C,
Being super low thermal conductive, yet vapor permeable, compression resistant and resilient, inorganic and inflammable profile, easy processing with reduced volume, and environmentally safe. AMAGEL HT1000 Series is the state-of-art product which is the perfect choice for those in need of the best insulation performance with minimum thickness while achieving minimum energy consumption. It is suitable for the insulation of pipes, tanks, containers and other industrial applications for the thermal protection and fireproofing. AMAGEL HT1000 is the perfect solution for those who need to improve the performance of insulation and significantly reduce energy consumption.
Applications
- Medium and high temperatures industrial furnaces ·Removable escape capsule
- Special military equipments
- All high temperature industrial applications
Physical Properties
Product Form | Sheet |
Standard Thickness | 10mm |
Length and Width | 1000 * 500 mm |
Thermal Conductivity | 0.021w/m·k (at 25°C) |
Max Use Temperature | +1000°C |
Density | 280 ± 40 kg/m3 |
Hydrophobic | No |
AMAGEL HTR1000
Insulation Panel for High-Temp Industrial Applications and Special Equipments
- Superior Insulation Performances
2~5 times better insulation performance than traditional materials, achieving same and even better insulation performance with minimum insulation thickness
- Vapor Permeable
Vapor permeability help to prevent Corrosion Under Insulation(CUI)
- Compression Resistent yet resilient
Strong structural strength provides protection for targeted objects
- Inorganic and Inflammable Profile
Enables stable performance over long term while providing fire protection to objects
- Easy for Handling and Installation
Can be cut on site easily with conventional cutting tools to fit any specific shape or geometry
- Less Volume for Storage and Transportation
Less volume needed for insulation materials, sharply reducing volume and cost for storage and transportation
- Enviromentally Safe
Composed of inorganic materials, landfill disposable
AMAGEL HTR1000 is a series of rigid, nano-porous panels designed for different thickness, temperature and high compressive strength insulation in construction, machinery and other applications.
Aerogel is the lowest thermal conductive of any present- recognized solid. With a new nanotechnology, AMAGEL HTR1000 Series combines the nano-sized silica aerogel with fibers which makes it the leading product in the industry.
AMAGEL HTR1000 carrying the excellent properties including extremely low thermal conductivity, environmental-safety, easy-utilization, and hydrophobicity(only applicable for hydrophobic version), is the ultimate choice for those seeking better insulation effect.